Technote : Status Code 58

Troubleshooting Status Code 58

STATUS CODE 58: Can't connect to client. Troubleshooting procedures for Status 58 errors.

Exact Error Message
status code 58: can't connect to client

Details:
Overview:
A status 58 error results from either a TCP SYN request sent to a client from the NetBackup (NBU) server that was not acknowledged or the server was not resolvable so a TCP SYN request was not sent. The majority of the causes of this issue are due to the client not listening on the BPCD or VNETD ports, the master server unable to resolve the client by hostname, or the client can not resolve the NBU server by its IP address. NBU clients running 6.x release, though it uses the vnetd daemon for incoming connections, it still requires bpcd to perform the hostname compare to authenticate the NBU server.

Troubleshooting:
Below are steps you can use to help isolate the issue.

When troubleshooting status 58 errors on a NetBackup client, the first thing to test is to whether or not you can access the client from the client Host Properties from the master server. If that works the same ports are involved when backing up the client as to when you access the client host properties. Connecting to the client host properties from the master server would prove the master server can access the client without any problems. So if using a storage unit on the master server you should be able to backup the client without getting the status 58 error.

In 6.x environments you can use the command- bptestbpcd to verify you can connect to both the vnetd and bpcd ports on the client server.
e.g.
bptestbpcd -verbose -debug -client

See the tech note 277901 for additional details on use of that command. http://entsupport.symantec.com/docs/277901

If still getting status 58 errors after ensuring the master server can connect to the client, focus on the media server used during the backup. The problem is more than likely with the client hostname lookup or gethostbyname call made to DNS or local host file on the media server.

If the master server can not connect to the client when trying to access the client host properties, or the point of failure appears to be with the media server, below are steps you can take to further troubleshoot this issue-

To test the master/media server resolution of the client server hostname run the following command-
/netbackup/bin/./bpclntcmd -hn

Since reverse lookups is part of the NBU server to client connections make sure the client can also be resolved by its IP address-
/netbackup/bin/./bpclntcmd -ip

On the client test the resolution of the NBU servers by issuing the same commands. These commands should be run against all of the media servers that may be trying to backup the client server-
/netbackup/bin/./bpclntcmd -hn

/netbackup/bin/./bpclntcmd -ip

Verify you are able to "ping" the client's IP address from the NBU server. If this fails consult with your Network Administrator and client server System Administrator to resolve the layer 3 or IP network connectivity. Double check the server's NIC's IP address and netmask to ensure they are configured correctly.

A very useful command to help with testing client and server resolution is the command -
bpclntcmd -pn when run from a NBU client or media server.
What that command does when ran on a client as example,
1. The client gets the first server listed in it's server's list and knowing it is the master server does a forward lookup of that hostname or a gethostbyname call to DNS or host file.
2. Once that is successful you should see the message-"expecting response from (master server hostname)". If the forward lookup fails or the client does not have the bprd port 13720 defined in the registry for Windows clients or in /etc/services for UNIX clients you will not see that message displayed. Create a bplist log on the client at verbose 5 and rerun that command.
3. When the client connects to the bprd port on the master server, the master server performs two functions. It first does a simple reverse lookup of the incoming IP address and that is the first name returned by the command. Then it goes into the policy database and lookup what hostname it is using when backing up the client server. That is the second hostname returned by the command. See the example below-

In this example the client hostname is dotto.veritas.com and the master server is hal9000.veritas.com-

C:\Program Files\VERITAS\NetBackup\bin>bpclntcmd -pn
expecting response from server hal9000.veritas.com
dotto.veritas.com dotto.veritas.com 10.82.110.6
3412
  • Creating a bplist log on the client at verbose 5 should show the attempt to resolve the master server and make a connection request to the NBU server.
  • Creating a bprd log on the master server should show the incoming connection as well.
  • The same bprd log when create on the master server would show the attempt to connect to the client using the client host properties.

Resolution:
The next step if the client is still failing with a status 58 after you verified the servers are resolvable to each other using the bpclntcmd command, is to ensure the client server has the bpcd port in listening mode-

For Windows clients-
netstat -a and look for the BPCD and VNETD port are listening-
e.g.
TCP dotto:vnetd dotto.veritas.com:0 LISTENING
TCP dotto:bpcd dotto.veritas.com:0 LISTENING

For UNIX client verify the ports are listening by issuing the same command-

# netstat -a |grep bpcd
*.bpcd *.* 0 0 49152 0 LISTEN

#netstat -a |grep vnetd
*.vnetd *.* 0 0 49152 0 LISTEN

For Windows clients if it not listening on the ports verify bpinetd is running on the client using task mgr.


For UNIX clients verify BPCD and VNETD are defined in /etc/service and inetd-
# vi /etc/services
bpcd 13782/tcp bpcd
vnetd 13724/tcp vnetd

# vi /etc/inetd.conf
bpcd stream tcp nowait root /usr/openv/netbackup/bin/bpcd bpcd
vnetd stream tcp nowait root /usr/openv/bin/vnetd vnetd

For UNIX client server if the /etc/services file for bpcd shows it is using tcpd then there is a TCP wrapper on the bpcd port 13782-
This example shows a TCP wrapper running on the bpcd port when defined in inetd.conf-
bpcd stream tcp nowait root /usr/local/bin/tcpd /usr/openv/netbackup/bin/bpcd bpcd


Locally on the client create a bpcd log and increase the verbose level to 5.

On the client server to test whether the bpcd binary is executable and will generate a log issue the following command-
UNIX- netbackup/bin/./bpcd

Windows- program files\VERITAS\netbackup\bin:bpcd

That should generate the following log entry and prove the binary is executable and generates a log entry-

BPCD log. You should see something like this -
16:47:45.986 [5296.3376] <2> bpcd main: offset to GMT 21600
16:47:45.986 [5296.3376] <2> bpcd main: Got socket for input 3
16:47:46.017 [5296.3376] <2> logconnections: getsockname(3) failed: 10038
16:47:46.017 [5296.3376] <16> bpcd setup_sockopts: setsockopt 1 failed: h_errno 10038
16:47:46.017 [5296.3376] <2> bpcd main: setup_sockopts complete
16:47:46.158 [5296.3376] <2> vauth_acceptor: ..\libvlibs\vauth_comm.c.332: Function failed: 17 0x00000011
16:47:46.158 [5296.3376] <16> bpcd main: authentication failed: 17

It is normal to have it end with the <16> bpcd main: authentication failed: 17 error. But this test proves the binary is functioning correctly.

Then to test the bpcd port locally on the client server from the command prompt, run this telnet test using the loopback interface-

telnet localhost 13782 or

telnet 127.0.0.1 13782

That telnet to the loopback interface using the localhost hostname should generate a log that looks like this-

16:49:35.352 [3336.4360] <2> bpcd main: offset to GMT 21600
16:49:35.352 [3336.4360] <2> bpcd main: Got socket for input 376
16:49:35.352 [3336.4360] <2> logconnections: BPCD ACCEPT FROM 127.0.0.1.3845 TO 127.0.0.1.13782
16:49:35.352 [3336.4360] <2> bpcd main: setup_sockopts complete
16:49:35.414 [3336.4360] <2> bpcd peer_hostname: Connection from host localhost (127.0.0.1) port 3845
16:49:35.414 [3336.4360] <2> bpcd valid_server: comparing hal9000.veritas.com and localhost
16:49:35.414 [3336.4360] <4> bpcd valid_server: localhost is not a master server
16:49:35.414 [3336.4360] <16> bpcd valid_server: localhost is not a media server either
16:49:39.189 [3336.4360] <16> bpcd main: read failed: The operation completed successfully.

It generates the <16> error because it does not understand what telnet is and also fails to authenticate the localhost as a NBU server.

For Linux clients if they are missing a library file required by bpcd or vnetd you would get this type of error message-

telnet localhost bpcd
Trying 127.0.0.1...
Connected to clientname.domainname.com
Escape character is '^]'.
bpcd: error while loading shared libraries: libstdc++-libc6.2-2.so.3:
cannot open shared object file: No such file or directory

Contact the OS vendor to obtain the required library file.

If the telnet to localhost works try the same telnet test from the master server using the client hostname to the bpcd port-
telnet (client hostname) 13782

That should generate a log entry as seen below showing the master server being accepted-

16:52:46.077 [1160.5436] <2> bpcd main: offset to GMT 21600
16:52:46.077 [1160.5436] <2> bpcd main: Got socket for input 400
**The client sees the incoming connection from the master server using the IP address 10.82.105.254**
16:52:46.077 [1160.5436] <2> logconnections: BPCD ACCEPT FROM 10.82.105.254.44554 TO 10.82.110.6.13782
16:52:46.077 [1160.5436] <2> bpcd main: setup_sockopts complete
**Performs a reverse lookup of the incoming IP address and gets the hostname**
16:52:46.092 [1160.5436] <2> bpcd peer_hostname: Connection from host hal9000.veritas.com (10.82.105.254) port 44554
**Then compares the hostname to the server list on the client**
16:52:46.092 [1160.5436] <2> bpcd valid_server: comparing hal9000.veritas.com and hal9000.veritas.com
**The hostname compare succeeds**
16:52:46.092 [1160.5436] <4> bpcd valid_server: hostname comparison succeeded
16:52:49.476 [1160.5436] <16> bpcd main: read failed: The operation completed successfully.

If any of these telnet tests fails to generate a log entry then there is something outside of NBU that is preventing access to the client's port. Most likely firewall software or a TCP wrapper was placed on the ports. Checking what services the client is running for Windows clients (Try Turning off MS firewall software for a quick test) or check the host.allow/deny files on the UNIX clients would be a good place to review next.

For UNIX clients you can try removing the BPCD port from inetd.conf and run the command "bpcd -standalone" to see if that gets the port listening.

Note: When testing connections to bpcd note the delta time difference between the bpcd log message e.g. "16:52:46.077 [1160.5436] <2> logconnections: BPCD ACCEPT FROM 10.82.105.254.44554 TO 10.82.110.6.13782 " and the log message "16:52:46.092 [1160.5436] <4> bpcd valid_server: hostname comparison succeeded" Due to the hard coded bprbm timeout of 1 minute this time difference can not exceed 60 seconds. If it exceeds that timeout then try using a host file entry to avoid DNS latency.

If the client had been working at NBU 5.x release but now fails after upgrading to NBU 6.x, you can try using 5.x defaults for the client connection to see if that gets the failing client working again. To do so, from the Administration Console:
1. Launch the NetBackup Administration Console, connecting to the master server
2. Expand Host Properties in the left pane
3. Select Master Server in the left pane
4. Click the name of the master server in the right pane
5. Select the Client Attributes section
6. Add the name of the client in question if it isn't listed
7. In the Connect Options tab for the client, make the following changes:
BPCD connect back -> "Random port"
Ports -> "Reserved port"
Daemon connection port -> "Daemon port only"

Note: You DO NOT have to stop and restart when making changes to the master server client attribute tab. Just simply click apply and okay to commit those changes